Hot Runner Coil Heaters
Hot runner spring coil heaters for nozzle and hot runner heating applications. KINPAW offers standard 220V configurations and options for thermocouples, protective covers and custom dimensions.
Standard listed configurations are shown below. Please confirm current stock, dimensions and electrical details before ordering.
Request a Quote View Standard Sizes
Hot Runner Spring Coil Heater Overview
Hot runner coil heaters are formed into a spring-like coil to fit around a hot runner nozzle or other cylindrical heating area. The coil dimensions and electrical output should be selected to match the equipment design and required heating conditions.
Product Features & Options
Spring Coil Design
Coiled construction designed for fitting around hot runner nozzles. Inner diameter and height should be matched to the installation dimensions.
Thermocouple Options
Optional built-in J-type or K-type thermocouple for temperature sensing, subject to the selected construction.
Protective Cover
An optional stainless steel outer cover can be specified where required by the application.
Lead Configuration
Standard lead length is 1 meter. Side-exit and end-exit lead arrangements are available options.
Surface Finish
Bright and sandblasted surface finishes are listed as available options.
Custom Construction
Special inner diameters, unusual shapes and segmented power designs can be discussed according to drawings or samples.
Common Coil Cross-Sections
The following are the common heating element cross-sections identified in the supplied product information. Availability may vary by supplier and stock batch.
2.2 × 4.2 mm
Common rectangular / flat profile, often selected for compact nozzle heater constructions.
3.0 × 3.0 mm
Common square profile for hot runner spring coil heater configurations.
3.5 × 3.5 mm
Additional square profile option, subject to availability.
4.0 × 4.0 mm
Larger square profile identified for higher-power configurations; confirm design suitability before selection.
Standard Hot Runner Coil Heater Sizes
The table below lists the 27 standard configurations supplied for this page. All listed configurations are 220V.
| No. | Inner Diameter × Height (mm) | Voltage | Power |
|---|---|---|---|
| 1 | Φ10 × 30 | 220V | 100W |
| 2 | Φ12 × 35 | 220V | 120W |
| 3 | Φ14 × 40 | 220V | 150W |
| 4 | Φ16 × 40 | 220V | 180W |
| 5 | Φ16 × 50 | 220V | 220W |
| 6 | Φ18 × 40 | 220V | 200W |
| 7 | Φ18 × 50 | 220V | 260W |
| 8 | Φ20 × 40 | 220V | 240W |
| 9 | Φ20 × 50 | 220V | 300W |
| 10 | Φ20 × 60 | 220V | 360W |
| 11 | Φ22 × 50 | 220V | 320W |
| 12 | Φ22 × 60 | 220V | 380W |
| 13 | Φ25 × 50 | 220V | 350W |
| 14 | Φ25 × 60 | 220V | 420W |
| 15 | Φ25 × 80 | 220V | 520W |
| 16 | Φ28 × 60 | 220V | 480W |
| 17 | Φ28 × 80 | 220V | 600W |
| 18 | Φ30 × 60 | 220V | 500W |
| 19 | Φ30 × 80 | 220V | 650W |
| 20 | Φ30 × 100 | 220V | 750W |
| 21 | Φ32 × 80 | 220V | 700W |
| 22 | Φ32 × 100 | 220V | 820W |
| 23 | Φ35 × 80 | 220V | 780W |
| 24 | Φ35 × 100 | 220V | 900W |
| 25 | Φ38 × 100 | 220V | 1000W |
| 26 | Φ40 × 100 | 220V | 1100W |
| 27 | Φ42 × 120 | 220V | 1300W |
Important: These are standard reference configurations provided for the KINPAW product page. Actual stock may vary. Please confirm availability, dimensions, power and lead options with us before placing an order.
Technical Specifications
| Item | Specification |
|---|---|
| Product type | Hot runner spring coil heater |
| Standard voltage | 220V |
| Standard lead length | 1 meter |
| Common cross-sections | 2.2 × 4.2 mm / 3.0 × 3.0 mm |
| Other cross-sections | 3.5 × 3.5 mm / 4.0 × 4.0 mm, subject to availability |
| Thermocouple | Optional J-type / K-type, built-in sensing wire |
| Outer cover | Optional stainless steel cover |
| Lead exit | Side exit / end exit |
| Surface finish | Bright / sandblasted |
| Reference maximum temperature | Up to approximately 600°C, depending on construction and operating conditions |
| Reference watt density | Normally up to 9 W/cm²; confirm for the selected design |
Temperature and watt-density figures are reference values, not a blanket guarantee for every size or configuration. Actual limits depend on heater construction, installation, temperature control and operating conditions.
Applications
Hot Runner Nozzles
Heating around hot runner nozzle assemblies in injection molding systems.
Injection Molding Molds
Heating components used in plastic injection molding equipment.
Sprue & Runner Components
Coil heater configurations for compatible cylindrical hot runner components.
Custom Hot Runner Coil Heaters
When a standard configuration does not match the equipment, custom options can be discussed based on a technical drawing, sample or confirmed dimensions.
- Special inner diameter and coil height
- Non-standard cross-section or coil shape
- Segmented or multi-section power design
- Alternative voltage, including 110V or 380V, subject to confirmation
- Extended lead length and customized lead orientation
- Optional J-type or K-type thermocouple and stainless steel outer cover
Non-standard sizes, unusual shapes, segmented power and special voltage configurations generally require customization. Production feasibility and lead time are confirmed after reviewing the requirements.
How to Select a Hot Runner Coil Heater
1. Confirm Dimensions
Provide the required coil inner diameter and height. Confirm the actual nozzle dimensions and installation clearance.
2. Confirm Electrical Data
Specify voltage and power. The listed standard configurations use 220V.
3. Confirm Options
Choose the cross-section, lead exit direction, lead length, thermocouple type and outer cover if required.
Quick Size Reference
- Φ10–Φ20: may be considered for smaller nozzles and compact hot runner components.
- Φ20–Φ30: may be considered for medium-size nozzle configurations.
- Φ32–Φ42: may be considered for larger-diameter or longer nozzle configurations.
These ranges are preliminary screening references only. Confirm the actual nozzle dimensions, coil fit, heating requirements and equipment specifications before selection.
Frequently Asked Questions
What voltage is used for the standard hot runner coil heaters?
The standard configurations listed on this page are 220V. Other voltages, such as 110V or 380V, generally require confirmation and customization.
What is the standard lead length?
The standard lead length is 1 meter. Extended lead lengths can be discussed as a custom option.
Can the coil heater include a thermocouple?
Yes. J-type and K-type built-in thermocouple options are available, subject to the selected construction.
Which cross-sections are available?
The common profiles are 2.2 × 4.2 mm and 3.0 × 3.0 mm. Other listed profiles include 3.5 × 3.5 mm and 4.0 × 4.0 mm; please confirm availability.
Can you make a custom inner diameter or coil height?
Special inner diameters, heights and other non-standard dimensions can generally be made to order. Please provide a drawing or sample for review.
Are all 27 sizes always in stock?
Stock levels can vary. Please contact KINPAW to confirm the availability of the exact size, voltage, power and options you need.
What information should I provide for a quotation?
Please provide inner diameter, height, voltage, power, cross-section, lead length and exit direction, thermocouple requirement, outer cover requirement, and a drawing or sample photo if available.
Looking for a Hot Runner Coil Heater?
Send KINPAW your required dimensions, voltage, power and optional features. Our team can review the specifications and help identify a suitable standard or custom configuration.
Contact KINPAW for a Quote