Industrial Thermocouples

Temperature sensing solutions for industrial equipment, machinery and process applications.

KINPAW supplies industrial thermocouples in several practical configurations, including probe-type, threaded, spring-loaded bayonet and platinum-rhodium thermocouples with alumina protection tubes.

Standard dimensions are available in multiple probe diameters, lengths and mounting thread configurations. Custom lead lengths, special threads and other non-standard requirements can also be discussed.

Request a Quote
KINPAW industrial thermocouples for temperature measurement

Thermocouple Types and Designs

Different equipment and installation conditions require different thermocouple structures. KINPAW offers the following product configurations.

Probe-Type Thermocouples

Straight probe construction with a metal protection sheath and no mounting thread. Available in multiple probe diameters and lengths.

Threaded Thermocouples

Threaded mounting designs for installation in compatible equipment and measurement points. Metric and selected G thread options are available.

Spring-Loaded Bayonet Thermocouples

Bayonet-style mounting with a compression spring. Designed for compatible measurement positions requiring spring-loaded contact.

Platinum-Rhodium Thermocouples

High-temperature thermocouple assemblies with alumina protection tubes. Available in selected standard dimensions.

1. Probe-Type Thermocouples

Probe-type thermocouples feature a straight metal protection tube without a mounting thread. They are available in different diameters and probe lengths.

Stainless steel Type K straight probe thermocouple
Stainless steel Type K probe thermocouple
Probe DiameterProbe Length
Φ3 mm50 mm
Φ3 mm100 mm
Φ3 mm150 mm
Φ4 mm50 mm
Φ4 mm100 mm
Φ4 mm150 mm
Φ4 mm200 mm
Φ5 mm50 mm
Φ5 mm100 mm
Φ5 mm150 mm
Φ5 mm200 mm
Φ6 mm50 mm
Φ6 mm100 mm
Φ6 mm150 mm
Φ6 mm200 mm
Φ6 mm300 mm
Φ8 mm100 mm
Φ8 mm200 mm
Φ8 mm300 mm
Φ10 mm100 mm
Φ10 mm200 mm
Φ10 mm300 mm
Standard configuration: Straight probe with metal protection sheath. Default lead length is 1 meter.

2. Threaded Thermocouples

Threaded thermocouples are designed for mounting in compatible threaded openings. Available thread types include selected metric threads and G threads.

M8 threaded thermocouple with metal probe
M8 threaded thermocouple
Mounting ThreadProbe DiameterProbe Length
M8 × 1.25Φ4 mm50 mm
M8 × 1.25Φ4 mm100 mm
M10 × 1.0Φ5 mm50 mm
M10 × 1.0Φ5 mm100 mm
M12 × 1.5Φ6 mm50 mm
M12 × 1.5Φ6 mm100 mm
M12 × 1.5Φ6 mm150 mm
M12 × 1.5Φ6 mm200 mm
M14 × 1.5Φ8 mm100 mm
M14 × 1.5Φ8 mm150 mm
M16 × 1.5Φ8 mm100 mm
M16 × 1.5Φ8 mm200 mm
G1/4″Φ6 mm100 mm
G1/4″Φ8 mm150 mm
G1/2″Φ8 mm150 mm
G1/2″Φ10 mm200 mm
Thread selection: Please confirm the thread standard, nominal size and pitch before ordering. Metric threads and G threads are different standards and should not be treated as interchangeable.

3. Spring-Loaded Bayonet Thermocouples

Spring-loaded bayonet thermocouples use an M12 × 1.5 bayonet mounting connection with a compression spring. The following probe diameters are available in the standard size range.

Spring-loaded bayonet thermocouple with compression spring
Spring-loaded bayonet thermocouple
Mounting TypeProbe Diameter
M12 × 1.5 BayonetΦ4 mm
M12 × 1.5 BayonetΦ5 mm
M12 × 1.5 BayonetΦ6 mm

These configurations are intended for compatible bayonet mounting positions. Please confirm the required mounting dimensions and installation arrangement before selection.

4. Platinum-Rhodium Type S Thermocouples with Alumina Protection Tubes

KINPAW also supplies platinum-rhodium Type S thermocouple assemblies with alumina protection tubes in the following standard dimensions.

Platinum rhodium Type S thermocouple with alumina ceramic protection tube
Platinum-rhodium Type S thermocouple with alumina protection tube
Protection Tube DiameterProtection Tube Length
Φ8 mm200 mm
Φ8 mm300 mm
Φ8 mm400 mm
Note: The platinum-rhodium Type S assembly is a separate product category from standard metal-sheathed probe designs. Please confirm measuring instrument compatibility and the required temperature range when requesting a quotation.

Available Thermocouple Types

Thermocouples are available in different thermocouple types according to the required temperature measurement range, environment and instrument compatibility.

Type K

A commonly used thermocouple type for general industrial temperature measurement.

Type J

Used in various industrial temperature measurement applications where the sensor and instrument are compatible.

Type R

A platinum-rhodium thermocouple type used in specialized high-temperature measurement applications.

Type S

A platinum-rhodium thermocouple type used in specialized high-temperature measurement applications.

Type B

A platinum-rhodium thermocouple type used for specialized high-temperature measurement applications.

Thermocouple type, protection tube construction, temperature range and instrument input must be confirmed together before ordering.

Custom Thermocouple Options

In addition to the standard dimensions listed above, KINPAW can discuss customized thermocouple configurations according to equipment requirements.

Custom Probe Length

Non-standard probe lengths and lead lengths can be discussed.

Special Thread Sizes

Special mounting threads and non-standard connection dimensions can be requested.

Explosion-Proof Designs

Explosion-proof configurations may be available by customization. Required certification and application details must be confirmed.

Application-Based Configuration

Probe dimensions, mounting style and thermocouple type can be discussed based on the measurement point and equipment.

Standard lead length: 1 meter. Non-standard lead lengths, special threads and explosion-proof designs generally require customization.

How to Select the Right Thermocouple

To identify a suitable thermocouple, consider the following details:

  • Thermocouple type: K, J, R, S or B, according to the required measurement range and instrument compatibility.
  • Probe diameter: Select according to the available installation space and measurement point.
  • Probe length: Confirm the required insertion depth or protection tube length.
  • Mounting connection: Specify a straight probe, metric thread, G thread or bayonet connection.
  • Protection material: Confirm the required metal protection sheath or alumina protection tube.
  • Lead length: Standard lead length is 1 meter; other lengths can be requested.
Important: Probe diameter and length alone do not determine thermocouple suitability. Temperature range, process environment, sensor type, protection material and instrument compatibility should also be checked.

Frequently Asked Questions

What types of thermocouples does KINPAW offer?

KINPAW offers Type K, Type J, Type R, Type S and Type B thermocouple options. Product structures include probe-type, threaded, spring-loaded bayonet and platinum-rhodium designs with alumina protection tubes.

What is the standard lead length?

The default lead length is 1 meter. Non-standard lead lengths can be discussed according to installation requirements.

What is the difference between probe-type and threaded thermocouples?

Probe-type thermocouples have a straight metal protection sheath without a mounting thread. Threaded thermocouples use a threaded connection for installation in compatible equipment.

What is a spring-loaded bayonet thermocouple?

It is a thermocouple design using a bayonet mounting connection and compression spring. The mounting arrangement must match the equipment installation point.

Are platinum-rhodium thermocouples available?

Yes. KINPAW lists platinum-rhodium Type S thermocouple assemblies with alumina protection tubes in Φ8 × 200 mm, Φ8 × 300 mm and Φ8 × 400 mm configurations.

Can thermocouples be customized?

Yes. Non-standard lead lengths, special threads and other customized configurations can be discussed. Explosion-proof versions require confirmation of the application and certification requirements.

What information is needed for a quotation?

Please provide the thermocouple type, probe diameter, probe length, mounting thread if applicable, lead length, quantity and application details. A drawing or photo of the existing sensor can also help.

Looking for Industrial Thermocouples?

Send KINPAW your required thermocouple type, dimensions, mounting connection and application details. We can help you identify a suitable standard configuration or discuss a customized solution.

Contact KINPAW for a Quote
滚动至顶部