Mica Band Heaters

Reliable cylindrical heating solutions for injection molding, extrusion and plastic processing equipment.

KINPAW Mica Band Heaters are designed for external heating of machine barrels, cylinders and other compatible cylindrical surfaces. Standard models feature a stainless steel SS304 outer sheath, mica insulation and nickel-chromium resistance wire.

Choose from 38 standard 220V configurations or request a customized heater to match your equipment dimensions and installation requirements.

Request a Quote
KINPAW stainless steel mica band heater for industrial injection molding and extrusion machines

Mica Band Heater Features

Designed for practical industrial heating applications, KINPAW mica band heaters combine a compact construction with flexible installation options.

SS304 Stainless Steel Sheath

Standard outer sheath made from SS304 stainless steel for industrial heating applications.

Mica Insulation

Mica insulation separates the nickel-chromium resistance wire from the metal sheath.

Multiple Size Options

38 standard 220V models covering inner diameters from 25 mm to 140 mm.

Flexible Lead Options

Standard side-exit wiring or short-tail lead configurations.

Thermocouple Hole Option

Optional reserved K-type or J-type thermocouple hole, subject to configuration.

Custom Manufacturing

Custom dimensions, special cutouts, insulation layers and electrical configurations can be discussed.

Applications of Mica Band Heaters

Mica band heaters are commonly used to heat cylindrical metal surfaces in plastic processing machinery.

Injection Molding Machines

External barrel heating for injection molding equipment.

Plastic Extruders

Heating solutions for extrusion machine barrels and compatible cylindrical sections.

Blown Film Machines

Heating applications in blown-film production equipment.

Application note: Heater selection should be checked against the actual barrel diameter, heating width, operating temperature, installation clearance and electrical requirements.

Standard Mica Band Heater Sizes

KINPAW offers the following standard 220V model configurations. All dimensions are in millimeters. Φ represents the heater inner diameter, and H represents the heater height (width).

1. Small Barrels and Small Extruders (Φ25–Φ45 mm)

Inner Diameter × HeightVoltagePower
Φ25 × 25 mm220V60W
Φ25 × 30 mm220V70W
Φ30 × 25 mm220V70W
Φ30 × 30 mm220V90W
Φ30 × 35 mm220V100W
Φ35 × 35 mm220V120W
Φ35 × 40 mm220V150W
Φ40 × 30 mm220V130W
Φ40 × 40 mm220V180W
Φ45 × 40 mm220V200W

2. Common Injection Molding Machine Sizes (Φ50–Φ80 mm)

This size range includes many of the commonly stocked configurations for injection molding machine barrels.

Inner Diameter × HeightVoltagePower
Φ50 × 35 mm220V190W
Φ50 × 45 mm220V220W
Φ50 × 50 mm220V240W
Φ50 × 60 mm220V290W
Φ55 × 40 mm220V230W
Φ55 × 50 mm220V280W
Φ60 × 40 mm220V230W
Φ60 × 50 mm220V300W
Φ60 × 60 mm220V360W
Φ65 × 50 mm220V330W
Φ65 × 60 mm220V400W
Φ70 × 50 mm220V360W
Φ70 × 60 mm220V430W
Φ70 × 80 mm220V550W
Φ80 × 50 mm220V420W
Φ80 × 60 mm220V500W
Φ80 × 80 mm220V650W

3. Medium and Large Barrels, Blown Film and Extrusion Machines (Φ90–Φ140 mm)

Inner Diameter × HeightVoltagePower
Φ90 × 60 mm220V580W
Φ90 × 80 mm220V720W
Φ100 × 60 mm220V650W
Φ100 × 80 mm220V800W
Φ100 × 100 mm220V950W
Φ110 × 80 mm220V900W
Φ110 × 100 mm220V1050W
Φ120 × 80 mm220V1000W
Φ120 × 100 mm220V1200W
Φ130 × 100 mm220V1350W
Φ140 × 100 mm220V1500W
Stock availability: These are standard reference configurations. Actual stock availability may vary by supplier and production batch. Please confirm the required model before ordering.

Technical Specifications

SpecificationStandard Details
Heater TypeMica Band Heater
Standard Voltage220V
Outer SheathSS304 Stainless Steel
Insulation MaterialMica
Heating ElementNickel-Chromium Resistance Wire
Standard Thickness3.0–4.0 mm
Continuous Operating TemperatureUp to 350°C
Short-Term Peak TemperatureUp to 400°C
Typical Watt Density2.5–3.5 W/cm²
Lead ExitSide Exit / Short-Tail Lead
Optional Sensor ProvisionK-Type or J-Type Thermocouple Hole

Important: Temperature and watt density values are general product specifications, not a guarantee for every installation. Actual performance depends on heater dimensions, contact conditions, machine temperature, operating environment and installation.

Custom Mica Band Heater Options

For equipment with special dimensions or installation requirements, customized configurations can be discussed.

Thermocouple Hole

Optional reserved hole for K-type or J-type temperature sensing.

Extended Lead Wires

Lead length can be specified according to installation requirements.

Clamping Options

Clip-style configurations can be selected for compatible installations.

Insulation Layer

Additional insulation layer configurations are available by customization.

Special Cutouts

Flange notches, clearance openings and other special cutouts can be discussed.

Special Electrical Ratings

380V, special high-power and other non-standard electrical configurations require customization.

Usually customized: Insulation cotton layers, air-cooling grooves, flange clearance notches, 380V versions, diameters above 140 mm and non-standard heights are generally not standard stock items.

How to Select a Mica Band Heater

Use the following guide as an initial reference when identifying a suitable size range:

Φ25–Φ45 mm

For small injection molding equipment and small extrusion barrels.

Φ50–Φ80 mm

Common size range for standard injection molding machine barrels.

Φ90–Φ140 mm

For medium and larger barrels, blown-film machines and extrusion equipment.

Before ordering, please confirm the following details:

  • Actual barrel outside diameter and required heater inner diameter.
  • Required heater height (width).
  • Rated voltage and power.
  • Lead exit direction and required lead length.
  • Thermocouple hole position, if required.
  • Installation clearance, clamping method and any special cutouts.
Selection reminder: The diameter ranges above are only for preliminary model screening. Final selection must be checked against the actual machine dimensions and operating conditions.

Mica Band Heaters vs. Ceramic Band Heaters

Mica band heaters and ceramic band heaters are different product types. They use different insulation structures and have different operating characteristics.

ItemMica Band HeaterCeramic Band Heater
Insulation StructureMica InsulationCeramic Insulating Components
Heating ElementNickel-Chromium Resistance WireResistance Wire
Typical ApplicationsInjection molding and extrusion barrelsApplications requiring a different heater structure or higher temperature capability
Product SelectionBased on mica heater specificationsBased on ceramic heater specifications

Do not select a ceramic band heater as a direct replacement for a mica band heater without checking dimensions, electrical ratings, installation conditions and temperature requirements.

Frequently Asked Questions

What is a mica band heater used for?

Mica band heaters are commonly used for external heating of cylindrical surfaces, including injection molding machine barrels, extrusion machine barrels and blown-film equipment.

What is the standard voltage of KINPAW mica band heaters?

The standard configurations listed on this page are rated at 220V. Other voltage options, including 380V, generally require customization.

What materials are used in the standard mica band heater?

The standard configuration uses an SS304 stainless steel outer sheath, mica insulation and nickel-chromium resistance wire.

Can a mica band heater include a thermocouple hole?

Yes. A reserved hole for a K-type or J-type thermocouple can be selected, subject to the required position and heater design.

Can KINPAW customize the heater dimensions?

Customized inner diameters, heights, lead lengths, cutouts and other installation details can be discussed. Please provide your equipment dimensions and electrical requirements.

What is the difference between mica and ceramic band heaters?

Mica and ceramic band heaters use different insulation structures and have different operating characteristics. They should be selected according to the equipment design and actual temperature requirements.

How do I request a quotation?

Please provide the required inner diameter, heater height, voltage, wattage, lead configuration and quantity. A drawing or photo of the existing heater can also help clarify the requirements.

Looking for Mica Band Heaters?

Send KINPAW your heater dimensions, voltage, wattage and installation requirements. Our team can help you identify a suitable standard configuration or discuss a customized solution.

Contact KINPAW for a Quote
滚动至顶部