Industrial Thermocouples
Temperature sensing solutions for industrial equipment, machinery and process applications.
KINPAW supplies industrial thermocouples in several practical configurations, including probe-type, threaded, spring-loaded bayonet and platinum-rhodium thermocouples with alumina protection tubes.
Standard dimensions are available in multiple probe diameters, lengths and mounting thread configurations. Custom lead lengths, special threads and other non-standard requirements can also be discussed.
Request a Quote
Thermocouple Types and Designs
Different equipment and installation conditions require different thermocouple structures. KINPAW offers the following product configurations.
Probe-Type Thermocouples
Straight probe construction with a metal protection sheath and no mounting thread. Available in multiple probe diameters and lengths.
Threaded Thermocouples
Threaded mounting designs for installation in compatible equipment and measurement points. Metric and selected G thread options are available.
Spring-Loaded Bayonet Thermocouples
Bayonet-style mounting with a compression spring. Designed for compatible measurement positions requiring spring-loaded contact.
Platinum-Rhodium Thermocouples
High-temperature thermocouple assemblies with alumina protection tubes. Available in selected standard dimensions.
1. Probe-Type Thermocouples
Probe-type thermocouples feature a straight metal protection tube without a mounting thread. They are available in different diameters and probe lengths.
| Probe Diameter | Probe Length |
|---|---|
| Φ3 mm | 50 mm |
| Φ3 mm | 100 mm |
| Φ3 mm | 150 mm |
| Φ4 mm | 50 mm |
| Φ4 mm | 100 mm |
| Φ4 mm | 150 mm |
| Φ4 mm | 200 mm |
| Φ5 mm | 50 mm |
| Φ5 mm | 100 mm |
| Φ5 mm | 150 mm |
| Φ5 mm | 200 mm |
| Φ6 mm | 50 mm |
| Φ6 mm | 100 mm |
| Φ6 mm | 150 mm |
| Φ6 mm | 200 mm |
| Φ6 mm | 300 mm |
| Φ8 mm | 100 mm |
| Φ8 mm | 200 mm |
| Φ8 mm | 300 mm |
| Φ10 mm | 100 mm |
| Φ10 mm | 200 mm |
| Φ10 mm | 300 mm |
2. Threaded Thermocouples
Threaded thermocouples are designed for mounting in compatible threaded openings. Available thread types include selected metric threads and G threads.
| Mounting Thread | Probe Diameter | Probe Length |
|---|---|---|
| M8 × 1.25 | Φ4 mm | 50 mm |
| M8 × 1.25 | Φ4 mm | 100 mm |
| M10 × 1.0 | Φ5 mm | 50 mm |
| M10 × 1.0 | Φ5 mm | 100 mm |
| M12 × 1.5 | Φ6 mm | 50 mm |
| M12 × 1.5 | Φ6 mm | 100 mm |
| M12 × 1.5 | Φ6 mm | 150 mm |
| M12 × 1.5 | Φ6 mm | 200 mm |
| M14 × 1.5 | Φ8 mm | 100 mm |
| M14 × 1.5 | Φ8 mm | 150 mm |
| M16 × 1.5 | Φ8 mm | 100 mm |
| M16 × 1.5 | Φ8 mm | 200 mm |
| G1/4″ | Φ6 mm | 100 mm |
| G1/4″ | Φ8 mm | 150 mm |
| G1/2″ | Φ8 mm | 150 mm |
| G1/2″ | Φ10 mm | 200 mm |
3. Spring-Loaded Bayonet Thermocouples
Spring-loaded bayonet thermocouples use an M12 × 1.5 bayonet mounting connection with a compression spring. The following probe diameters are available in the standard size range.
| Mounting Type | Probe Diameter |
|---|---|
| M12 × 1.5 Bayonet | Φ4 mm |
| M12 × 1.5 Bayonet | Φ5 mm |
| M12 × 1.5 Bayonet | Φ6 mm |
These configurations are intended for compatible bayonet mounting positions. Please confirm the required mounting dimensions and installation arrangement before selection.
4. Platinum-Rhodium Type S Thermocouples with Alumina Protection Tubes
KINPAW also supplies platinum-rhodium Type S thermocouple assemblies with alumina protection tubes in the following standard dimensions.
| Protection Tube Diameter | Protection Tube Length |
|---|---|
| Φ8 mm | 200 mm |
| Φ8 mm | 300 mm |
| Φ8 mm | 400 mm |
Available Thermocouple Types
Thermocouples are available in different thermocouple types according to the required temperature measurement range, environment and instrument compatibility.
Type K
A commonly used thermocouple type for general industrial temperature measurement.
Type J
Used in various industrial temperature measurement applications where the sensor and instrument are compatible.
Type R
A platinum-rhodium thermocouple type used in specialized high-temperature measurement applications.
Type S
A platinum-rhodium thermocouple type used in specialized high-temperature measurement applications.
Type B
A platinum-rhodium thermocouple type used for specialized high-temperature measurement applications.
Thermocouple type, protection tube construction, temperature range and instrument input must be confirmed together before ordering.
Custom Thermocouple Options
In addition to the standard dimensions listed above, KINPAW can discuss customized thermocouple configurations according to equipment requirements.
Custom Probe Length
Non-standard probe lengths and lead lengths can be discussed.
Special Thread Sizes
Special mounting threads and non-standard connection dimensions can be requested.
Explosion-Proof Designs
Explosion-proof configurations may be available by customization. Required certification and application details must be confirmed.
Application-Based Configuration
Probe dimensions, mounting style and thermocouple type can be discussed based on the measurement point and equipment.
How to Select the Right Thermocouple
To identify a suitable thermocouple, consider the following details:
- Thermocouple type: K, J, R, S or B, according to the required measurement range and instrument compatibility.
- Probe diameter: Select according to the available installation space and measurement point.
- Probe length: Confirm the required insertion depth or protection tube length.
- Mounting connection: Specify a straight probe, metric thread, G thread or bayonet connection.
- Protection material: Confirm the required metal protection sheath or alumina protection tube.
- Lead length: Standard lead length is 1 meter; other lengths can be requested.
Frequently Asked Questions
What types of thermocouples does KINPAW offer?
KINPAW offers Type K, Type J, Type R, Type S and Type B thermocouple options. Product structures include probe-type, threaded, spring-loaded bayonet and platinum-rhodium designs with alumina protection tubes.
What is the standard lead length?
The default lead length is 1 meter. Non-standard lead lengths can be discussed according to installation requirements.
What is the difference between probe-type and threaded thermocouples?
Probe-type thermocouples have a straight metal protection sheath without a mounting thread. Threaded thermocouples use a threaded connection for installation in compatible equipment.
What is a spring-loaded bayonet thermocouple?
It is a thermocouple design using a bayonet mounting connection and compression spring. The mounting arrangement must match the equipment installation point.
Are platinum-rhodium thermocouples available?
Yes. KINPAW lists platinum-rhodium Type S thermocouple assemblies with alumina protection tubes in Φ8 × 200 mm, Φ8 × 300 mm and Φ8 × 400 mm configurations.
Can thermocouples be customized?
Yes. Non-standard lead lengths, special threads and other customized configurations can be discussed. Explosion-proof versions require confirmation of the application and certification requirements.
What information is needed for a quotation?
Please provide the thermocouple type, probe diameter, probe length, mounting thread if applicable, lead length, quantity and application details. A drawing or photo of the existing sensor can also help.
Looking for Industrial Thermocouples?
Send KINPAW your required thermocouple type, dimensions, mounting connection and application details. We can help you identify a suitable standard configuration or discuss a customized solution.
Contact KINPAW for a Quote